DSP Socket Issues
IC304 on DSP ASSY and IC504 on DSP3 ASSY.
Cold solder connections on these sockets can
cause loss of audio in DSP mode. For complete
loss of audio, at times associated with these
sockets, try resoldering socket to PCB first. At
the same time, clean and coat pins of socket and
IC with DeOxit, or similar compound. If this
doesn’t resolve the problem, remove the IC
socket and solder the IC directly to the board.